Abstract
Industrial X-ray CT has evolved into a popular solution in modern quality control applications,
such as in geometric dimensioning and tolerancing of metallic components. In a typical CT
metrology workflow, a surface is first determined from a CT reconstruction. However, the total
exposure time can be dramatically long to achieve adequate signal-to-noise (SNR) ratio to
accurately determine the surface for high-precision dimensional metrology. Hence, the
applicability of this tool to in-line (or online) metrology can be challenging for mm-sized metallic
components (e.g., automotive fuel injectors) demanding high (< 5 μm) surface resolution due to
low photons/pixel ratio.
Here, we evaluate two DL-based software packages – CTSegNet and DeepRecon for reducing
scanning time for measurements of the internal orifices (diameter of ~175 𝝁𝒎) of a steel fuel
injector in a Zeiss Versa 620. CTSegNet was developed by the first author (A. Tekawade) at
Argonne National Laboratory for direct surface determination from CT scan volumes. DeepRecon
was developed by ZEISS as a reconstruction engine for denoising volumes obtained from low-
dose scans. The main purpose of this paper is to analyze potential reductions in scanning time
when DL-based workflows are used to augment image-quality. A research fuel injector was
scanned using a ZEISS Versa 620 by acquiring a total of 3600 X-ray projections with 6 seconds
exposure per projection (total 6 hours). The data was reconstructed using equally spaced subsets
of those projections (e.g., 2X, 4X, 6X, 8X, 10X; where 4X means 900 projections) to mimic
reduced scan time. Each subset was reconstructed using DeepRecon Pro (DRPro, the latest version
of DeepRecon) as well as a traditional Feldkamp–Davis–Kress (FDK) reconstruction algorithm
and then thresholded to determine the surface. The data reconstructed by FDK was directly
binarized using CTSegNet. We conclude that variations in measurement accuracy of hole diameter
and cylindricity are expected to be in the order of 2 μm or less when using DRPro and CTSegNet
with a 10X throughput factor. In contrast the deviations produced by the FDK method are larger
than 2 μm and produce more noisy data, showing that DL-based workflows can increase the
throughput of CT acquisition while minimizing accuracy loss in dimensional data.
Cite this paper
Aniket Tekawade, Herminso Villarraga-Gómez, Matthew Andrew, Brandon A. Sforzo, Alan L. Kastengren, Christopher F. Powell. Argonne National Laboratory, Argonne, IL; Carl Zeiss Industrial Metrology; Carl Zeiss X-ray Microscopy. Presented at the Coordinate Metrology Systems Conference 2021, virtual conference, September 2021. Coordinate Metrology Society, reference CMS-2021-003.