Abstract
Optical scanners can collect millions of points of reasonable individual accuracy, and the advantages over touch probing are obvious enough – speed, coverage, ease of operation, price. So why has non-contact inspection not displaced the CMM? The paper's answer is that automatic extraction of actual dimensional and GD&T values from non-contact data is not yet a repeatable and reproducible procedure, and it works through the reasons: individual point accuracy still below a touch probe's, though the gap is closing; glossy and transparent surfaces that cause their own errors, though there are materials no touch probe can measure either; and the fundamentally different approaches the two kinds of data require.
Cite this paper
Gabor Lukacs, John Lockhart, Mike Facello. Geomagic, Inc., Research Triangle Park, NC. Presented at the Coordinate Metrology Systems Conference 2011, Phoenix, Arizona, July 25-29, 2011. Coordinate Metrology Society, reference CMS-2011-016.